The Role and Parameters of Terminal Ultrafiltration in Ultrapure Water Systems

2026-06-11

Terminal ultrafiltration in ultrapure water is the final, precision membrane barrier installed at the very end of the ultrapure water preparation system, between the Storage Tank and the point of use. Located after mixed bed, electrodeionization (EDI), or membrane degassing, it directly faces core processes such as wafer cleaning and chemical preparation, bearing the crucial mission of ensuring the physical purity of the final water.

I. The Core Functions of Terminal Ultrafiltration in Ultrapure Water

1. Particle Barrier and Colloid Control

During operation, desalination components at the end of the ultrapure water system (such as polishing mixed beds) may shed tiny resin fragments, and pipelines and valves may also generate micron or submicron-sized metal/polymer particles.

Terminal Ultrafiltration Membranes utilize a uniform, sponge-like pore structure to remove particles ≥0.03μm from water through "absolute retention," ensuring that the number of particles larger than 0.05μm in the product water is stably controlled below 1 particle/mL.

Furthermore, while colloidal silicon and colloidal iron in water do not affect conductivity, they can create hazy defects on the wafer surface. Terminal ultrafiltration effectively traps these, reducing the micro-roughness of the silicon wafer surface.

2. Thorough Removal of Microorganisms and Bacterial Endotoxins

Even in the low-nutrient environment of ultrapure water, oligotrophic bacteria may still exist. These bacteria often have a cell size greater than 0.2 μm, far exceeding the pore size of the ultrafiltration membrane. More importantly, terminal ultrafiltration can remove endotoxins (lipopolysaccharide aggregates) released after bacterial metabolism or death.

Terminal ultrafiltration membranes commonly used in the pharmaceutical industry have a molecular weight cutoff (MWCO) of 6000-10000 Daltons. Through size sieving, they completely remove endotoxin aggregates with a molecular weight greater than 10 kDa, resulting in endotoxin content in the product water below 0.03 EU/mL and a logarithmic removal value (LRV) > 7. In the semiconductor industry, killed bacterial residues are also a source of particulate matter; ultrafiltration can intercept these viable bacteria as well.

3. Reduce TOC and Improve Water Quality Stability

While most Total Organic Carbon (TOC) is decomposed into CO₂ by UV oxidation and then removed by degassing membranes, trace amounts of large-molecule organic matter can still be introduced through pipeline leaching and microbial metabolism.

Terminal ultrafiltration can effectively retain these high-molecular-weight organic matter above 10 kDa, providing approximately 10%–20% TOC buffering capacity to prevent instantaneous organic contamination from impacting the wafer surface or chemical solutions.

Simultaneously, it eliminates the instantaneous release of particles caused by pump start-up and shutdown or valve operation, ensuring extremely high cleanliness consistency of the water supply even under dynamic changes.

4. The Ultimate Physical Barrier for Process Point Protection

In scenarios such as semiconductor deep ultraviolet lithography, wafer cleaning, and water for injection preparation, any foreign nanoscale particles can lead to fatal defects.

Terminal ultrafiltration (TUL) is installed at the very end of the circulation loop or on a branch pipe at the point of use, forming a "zero-distance" physical barrier to ensure that secondary contamination does not occur in the extremely short pipeline from the ultrafiltration product outlet to the process point.

In pharmaceutical room-temperature water for injection systems, TUL is used as the final guarantee for achieving pyrogen-free distribution.

UF (20).jpg

II. Key Design Parameters of Terminal Ultrafiltration

The design of TUL needs to balance retention performance, product flux, operational life, and hygiene requirements. Parameter selection directly determines the quality of the ultrapure water supply.

1. Membrane Material and Configuration Selection

The mainstream choices are hydrophilic polyethersulfone (PES) or hydrophilic modified polyvinylidene fluoride (PVDF).

PES has excellent oxidation resistance, low solubility, and a wide pH tolerance range (1-14), and extremely low protein adsorption, making it a preferred material for both pharmaceutical and semiconductor applications.

PVDF has good chemical stability, especially suitable for ozone disinfection, but aging control is necessary under strong alkali and high temperature conditions.

The material must pass ANSI/NSF or USP biosafety testing, and the TOC increase in dissolved solids should be <10 ppb.

Almost all are hollow fiber membranes, suitable for both internal and external pressure applications. Internal pressure hollow fiber membranes are recommended for end-of-line ultrafiltration, where water permeates from the fiber lumen to the outside, creating a smooth flow path without dead zones and minimizing particle accumulation.

The fiber inner diameter is typically 0.8~1.2 mm, and the wall thickness is approximately 0.15~0.25 mm, ensuring sufficient mechanical strength while allowing for a membrane module packing density of 500~900 m²/m³.

2. Industry Differences in Retention Performance

Semiconductor/Electronics Industry: Focuses on removing submicron particles, commonly using ultrafiltration membranes with a nominal pore size of 0.03~0.05 μm (approximately corresponding to a 500,000 Da MWCO), emphasizing particle count control.

Pharmaceutical/Biotechnology: With pyrogen removal as the core objective, MWCO 10000Da (10kDa) or 6000Da membranes must be selected, and endotoxin challenge validation must be performed. The endotoxin level in the product water must be below 0.25 EU/mL (injection water standard), and ideally, it should be consistently below 0.03 EU/mL.

Some semiconductor processes with extremely stringent requirements (such as immersion lithography) also use 10kDa membranes, while also handling the removal of particles and large organic molecules.

3. Operating Modes and Recovery Rates

Dead-End Filtration: The mainstream mode for electronic-grade ultrapure water. The system is simple, performing automatic backwashing periodically, using its own product water as backwash water. The design flux is typically 60~120 LMH, with a recovery rate of 95%~98%. The backwash cycle is usually set to once every 30~60 minutes, combined with air scrubbing to improve the stripping effect.

Cross-Flow Filtration: Used in pharmaceutical injection water and some scenarios with extremely high pyrogen control requirements. Maintaining a concentrate-side tangential flow velocity of 0.5–1.5 m/s effectively reduces concentration polarization, increasing flux to 80–150 LMH. The design recovery rate is typically 85%–95%. Continuous concentrate discharge removes concentrated pyrogens. Concentrate is usually recycled back to the upstream storage tank or directly discarded.

4. Transmembrane Pressure Difference (TMP) and Pressure Resistance Design

During normal permeate operation, TMP should be controlled between 0.3 and 1.0 bar. Too low a TMP will prevent the maintenance of the design flux, while too high a TMP may compact the membrane pores or damage the membrane fibers. TMP should never exceed the membrane module's allowable upper limit of 2.0 bar.

Particularly critical is the permeate-side backpressure limitation. Hollow fiber membranes have weak backpressure resistance; therefore, the permeate-side pressure must not exceed that of the feed side. The design must include check valves and backpressure release devices on the permeate line to prevent membrane fiber rupture caused by backwashing misoperation or system fluctuations.

5. Integrity Testing Design

Each membrane module must have an automatic integrity test interface on the permeate side. Before system commissioning and during periodic testing, after immersing the membrane fibers, pressurize with clean compressed air to 1.0~1.5 bar. After stabilization, shut off the air supply and monitor the pressure drop over a specified time (e.g., 5 minutes). The standard is <0.05 bar. This test can detect the breakage of any membrane fiber and is an essential step to ensure the absolute effectiveness of the terminal barrier.

6. System Configuration and Material Hygiene Requirements

The terminal ultrafiltration unit inlet generally requires a 0.1μm security filter. Membrane housings and piping must be made of low-leaching materials such as PVDF, high-purity polypropylene, or PFA; PVC or plastics containing plasticizers are prohibited.

All instrument wetted parts must be polished to Ra≤0.8μm. Control systems should monitor inlet/permeate pressure, permeate flow rate, temperature, permeate particle count, and endotoxins in real time to ensure that any abnormalities trigger alarms and isolation immediately.