Leave Your Message

News

Why Is the Regeneration of Polishing Resins for Ultrapure Water Not Recommended?

Why Is the Regeneration of Polishing Resins for Ultrapure Water Not Recommended?

2026-04-02

Polishing resins used for ultrapure water are single-use, high-precision consumables; their regeneration is not recommended. The fundamental reason is that, following regeneration, the resin struggles to achieve the ppt-level purity required for ultrapure water applications, while the associated costs, risks, and performance degradation remain uncontrollable.

view detail
What are raw water, softened water, demineralized water, pure water, and ultrapure water?

What are raw water, softened water, demineralized water, pure water, and ultrapure water?

2026-03-20

Natural water or municipal water supply is not always "pure"; it contains various dissolved or suspended substances. Based on different levels of treatment and the degree of impurity removal, water can be classified into several levels: raw water, softened water, demineralized water, pure water, and ultrapure water. They are like different stations on the road to "ultimate purity."

view detail
Purified Water vs. Pure Water: A Single Word Difference, a World of Difference! Don't Use the "Water of Life" Wrong!

Purified Water vs. Pure Water: A Single Word Difference, a World of Difference! Don't Use the "Water of Life" Wrong!

2026-03-12

Introduction: In the laboratory, purified water is a "precision instrument" ensuring the safety of pharmaceutical solutions; in the supermarket, it's a readily available bottled water companion—both are called "water," but "purified water" and "purified water," though seemingly twins, actually shoulder completely different missions! Confusing them? The consequences could be serious!

view detail
How to Treat Wastewater? Let's Learn More

How to Treat Wastewater? Let's Learn More

2026-01-06

Why is Wastewater Treatment Necessary?

Water resources are an indispensable part of people's daily lives and production. As the world's largest water consumer, my country's total freshwater resources account for only 6% of global water resources, and its per capita freshwater availability is only 25% of the world average, indicating a scarcity of freshwater resources. Under these circumstances, strengthening water resource protection and improving water resource utilization efficiency through wastewater purification and reuse has become an extremely necessary task.

view detail
The Relationship Between Permeate Volume and Water Temperature in Reverse Osmosis (RO) Operation

The Relationship Between Permeate Volume and Water Temperature in Reverse Osmosis (RO) Operation

2025-12-30

Inlet water temperature is one of the most significant and direct operating parameters affecting the permeate volume of an RO system. With a constant inlet water pressure, the higher the inlet water temperature, the greater the permeate volume of the RO system; conversely, the lower the inlet water temperature, the significantly lower the permeate volume. This is not a simple linear increase, but its impact is very significant. The underlying scientific principles mainly involve the following two points:

view detail
Security Filter Design and Calculation Selection

Security Filter Design and Calculation Selection

2025-12-24

Security filters are mainly used to remove small particles (such as suspended solids, colloids, microorganisms, etc.) from liquids, protecting downstream equipment (such as reverse osmosis membranes, ion exchange resins, etc.). Their design and selection require comprehensive consideration of factors such as fluid properties, filtration accuracy, flow rate, pressure drop, and material compatibility. The following are the core steps and key points of design and calculation selection:

view detail
When starting a centrifugal pump, should you turn on the pump first or open the valve first?

When starting a centrifugal pump, should you turn on the pump first or open the valve first?

2025-12-19

The starting sequence of a water pump and the opening/closing status of the valves directly affect its operational safety and efficiency. Different pump types have drastically different starting methods due to differences in their working principles.

view detail
The Working Principle of Water Purification Equipment is Surprisingly Simple!

The Working Principle of Water Purification Equipment is Surprisingly Simple!

2025-12-17

The Working Principle of Water Purification Equipment is Surprisingly Simple! This article will guide you through the secrets of water treatment!

How exactly does a water purification system work? You'll understand after reading this article!

Do you know what's in the water you drink every day? Besides water, there are many other substances, some beneficial, such as minerals and trace elements, and some harmful, such as bacteria, heavy metals, pesticides, and residual chlorine. With increasing water pollution, is the water we drink safe?

view detail
Double-stage Reverse Osmosis EDI Ultrapure Water Equipment – ​​Meeting High-Standard Water Requirements

Double-stage Reverse Osmosis EDI Ultrapure Water Equipment – ​​Meeting High-Standard Water Requirements

2025-12-11

In EDI equipment, various ions in the feed water are removed after passing through the resin, purifying the water. This process utilizes the principle of ion exchange to remove ions from the water. Because a voltage is applied across the ion exchange membrane, water molecules are electrolyzed into H+ and OH- ions, which are then sent to regenerate the resin. Simultaneously, the ions exchanged by H+ and OH- ions are migrated to the concentrate chamber and discharged under the influence of a stable voltage and current power supply, thus achieving continuous regeneration and continuous use.

view detail
Process Analysis of Ultrafiltration Membranes in Water Treatment Applications (II)

Process Analysis of Ultrafiltration Membranes in Water Treatment Applications (II)

2025-12-09

Water Supply Quality Adjustment

【Adjustment of Water Supply Temperature】

The permeability of ultrafiltration membranes is directly related to temperature. The permeation rate of ultrafiltration membrane modules is generally tested with pure water at 25℃. The permeation rate of ultrafiltration membranes is directly proportional to temperature, with a temperature coefficient of approximately 0.02/1℃. That is, for every 1℃ increase in temperature, the permeation rate increases by approximately 2.0%.

view detail