Reverse osmosis (RO) is an advanced water purification technology widely adopted in China, designed to effectively remove impurities such as dissolved salts, organic matter, and bacteria from water. Utilizing semi-permeable membrane technology, this process applies pressure to allow water molecules to pass through a highly refined reverse osmosis membrane (RO membrane) with a pore size of 1/10,000 μm. This ensures the retention of pollutants, producing water that meets stringent physical, chemical, and hygiene standards for drinking. The clean water generated by reverse osmosis (RO) represents the highest level of purity among current technologies, achieving cleanliness levels approaching 100%. As a leading supplier in the industry, our factory in China specializes in delivering cutting-edge reverse osmosis systems tailored to meet your specific water purification needs.

    Products Video

    Products Description

    RO equipment is currently one of the most advanced systems for producing pure water in global water treatment technology. It features low operating costs, economic efficiency, ease of operation, and reliable performance, making it the preferred choice for businesses requiring pure water production. The production capacity of RO equipment is based on raw water at 25°C, which represents the standard production condition. Variations in water temperature and production conditions may influence the equipment's output capacity.
    Industrial reverse osmosis equipment must be configured with different processes according to specific water quality requirements. Water standards vary across industries, such as resistivity levels ranging from 18 MΩ·cm to 0.5 MΩ·cm and conductivity ranging from 20 μS/cm to 0.1 μS/cm. Therefore, it is essential to configure appropriate pretreatment systems, single-stage or double-stage reverse osmosis processes, and post-treatment systems (e.g., EDI electric demineralization systems, polishing mixed bed systems, ultraviolet sterilization, ozone generators, chlorine dioxide systems, etc.) to meet these diverse standards.
    Reverse Osmosis System (1)
    Reverse Osmosis System (2)

    Major Components

    1. Pretreatment System:
    • Multi-media Filter: Removes suspended solids, sediments, and other large particulate impurities.
    • Activated Carbon Filter: Adsorbs organic compounds, residual chlorine, odors, and other contaminants.
    • Softener: Eliminates calcium and magnesium ions from water to prevent scale formation.
    2. Reverse Osmosis Membrane:

    Core component, typically constructed of polyamide or cellulose acetate materials, with an extremely small pore size (approximately 0.0001 microns). It effectively intercepts dissolved salts, bacteria, viruses, and other microorganisms.

    3. High-Pressure Pump:

    Supplies sufficient pressure (generally ranging from 100 to 1000 psi) to enable water molecules to permeate through the reverse osmosis membrane.

    4. Post-treatment System:
    • UV Sterilizer: Provides additional sterilization by eliminating bacteria and viruses.
    • Ozone Generator: Utilized for disinfection and odor removal processes.
    5. Control System:
    • PLC Controller: Automates equipment operation and monitors parameters such as pressure, flow rate, and water quality.
    • Instruments: Devices such as pressure gauges, flow meters, and conductivity meters are employed for real-time monitoring and data collection.

    Products Specification

    Reverse osmosis feed water requirements
    Project Unit Indicator
    pH(25℃) - 4~11 (running) 2~11 (cleaning)
    Turbidity NTU <1.0
    Silt Density Index (SDI) - <5
    Free residual chlorine mg/L <0.1[1], Control to 0.0
    Iron mg/L <0.05(Dissolved oxygen >5mg/L)[2]
    Manganese mg/L <0.3
    Aluminum mg/L <0.1
    Water temperature[3] 5~45
    Note:
    [1] At the same time to meet the total dose of less than 1000 h.mg / L during the life of the membrane.
    [2] Iron oxidation rate depends on the iron content, dissolved oxygen concentration in water and water pH, when pH <6, dissolved oxygen <0.5mg/L, allowing the maximum Fe2+<4mg/L.
    [3] Reverse osmosis unit of the optimal design of the water temperature of 20℃ ~ 25℃.

    Advantages

    • Broad removal of impurities: Capable of removing not only inorganic salt ions but also various organic impurities from water.
    • No phase change during the water separation process, achieving a high desalination rate (up to 99.7%).
    • High water production capacity with compact equipment size, enabling skid-mounted installation or customization based on site dimensions.
    • Low energy consumption, automatic operation, and minimal investment cost.
    • Strong adaptability, wide application range, and no environmental pollution.
    Reverse Osmosis System (3)

    Scope of Application

    As the core treatment equipment for water desalination systems, reverse osmosis equipment, when combined with pretreatment and subsequent desalination systems, has been widely applied in water treatment, electronics, chemicals, pharmaceuticals, food and beverages, metallurgy, and environmental protection sectors.

    Frequently Asked Questions

    What standard conditions determine the production capacity of RO equipment?
    The production capacity of reverse osmosis (RO) equipment is calculated based on raw water at a standard temperature of 25°C. Variations in raw water temperature and actual production conditions can influence the overall output capacity of the system.
    Why is a pretreatment system necessary for reverse osmosis?
    A pretreatment system is essential to protect the RO membrane. It includes a multi-media filter to remove large particulates, an activated carbon filter to adsorb organic compounds and chlorine, and a softener to eliminate calcium and magnesium ions, preventing scale formation on the membrane.
    What is the filtration capability of the reverse osmosis membrane?
    The RO membrane is the core filtration component, with an extremely small pore size of approximately 0.0001 microns. This small structure allows it to effectively intercept dissolved salts, bacteria, viruses, and other microscopic contaminants, achieving a desalination rate of up to 99.7%.
    What are the feed water requirements for reverse osmosis systems?
    Feed water must meet specific criteria: a pH range of 4–11 during operation, turbidity under 1.0 NTU, a Silt Density Index (SDI) below 5, free residual chlorine under 0.1 mg/L, and a water temperature between 5°C and 45°C.
    Which industries commonly utilize reverse osmosis equipment?
    Due to its efficiency and high purity output, RO equipment is widely applied in electronics, chemical processing, pharmaceuticals, food and beverages, metallurgy, general water treatment, and environmental protection sectors.