Leave Your Message

Commercial Reverse Osmosis System Factory in China - Top Suppliers for Pure Drinking Water Solutions

Reverse osmosis (RO) is a cutting-edge water purification technology widely used by suppliers and factories in China. Utilizing semi-permeable membrane technology, RO effectively removes impurities such as dissolved salts, organic materials, and bacteria from water. The fundamental principle involves applying pressure to force water molecules through a reverse osmosis membrane with an incredibly small pore size of 1/10,000 μm. This process retains pollutants, ensuring that the water meets stringent physical and chemical standards for safe drinking. The clean water produced by this advanced reverse osmosis technology represents the highest purity achievable in water purification, boasting a cleanliness level close to 100%. Trust reliable suppliers and factories in China for your reverse osmosis solutions, ensuring access to the purest water available.

    Products Video

    Products Description

    RO equipment is currently one of the most advanced systems for producing pure water in global water treatment technology. It features low operating costs, economic efficiency, ease of operation, and reliable performance, making it the preferred choice for businesses requiring pure water production. The production capacity of RO equipment is based on raw water at 25°C, which represents the standard production condition. Variations in water temperature and production conditions may influence the equipment's output capacity.

    Industrial reverse osmosis equipment must be configured with different processes according to specific water quality requirements. Water standards vary across industries, such as resistivity levels ranging from 18 MΩ·cm to 0.5 MΩ·cm and conductivity ranging from 20 μS/cm to 0.1 μS/cm. Therefore, it is essential to configure appropriate pretreatment systems, single-stage or double-stage reverse osmosis processes, and post-treatment systems (e.g., EDI electric demineralization systems, polishing mixed bed systems, ultraviolet sterilization, ozone generators, chlorine dioxide systems, etc.) to meet these diverse standards.

    Reverse Osmosis System (1)
    Reverse Osmosis System (2)

    Major Components

    1

    Pretreatment System

    - Multi-media Filter: Removes suspended solids, sediments, and other large particulate impurities.
    - Activated Carbon Filter: Adsorbs organic compounds, residual chlorine, odors, and other contaminants.
    - Softener: Eliminates calcium and magnesium ions from water to prevent scale formation.
    2

    Reverse Osmosis Membrane

    Core component, typically constructed of polyamide or cellulose acetate materials, with an extremely small pore size (approximately 0.0001 microns). It effectively intercepts dissolved salts, bacteria, viruses, and other microorganisms.
    3

    High-Pressure Pump

    Supplies sufficient pressure (generally ranging from 100 to 1000 psi) to enable water molecules to permeate through the reverse osmosis membrane.
    4

    Post-treatment System

    - UV Sterilizer: Provides additional sterilization by eliminating bacteria and viruses.
    - Ozone Generator: Utilized for disinfection and odor removal processes.
    5

    Control System

    - PLC Controller: Automates equipment operation and monitors parameters such as pressure, flow rate, and water quality.
    - Instruments: Devices such as pressure gauges, flow meters, and conductivity meters are employed for real-time monitoring and data collection.

    Products Specification

    Reverse osmosis feed water requirements
    Project Unit Indicator
    pH(25℃)   4~11 (running) 2~11 (cleaning)
    Turbidity NTU <1.0
    Silt Density Index (SDI)   <5
    Free residual chlorine mg/L <0.1[1],Control to 0.0
    Iron mg/L <0.05(Dissolved oxygen >5mg/L)[2]
    Manganese mg/L <0.3
    Aluminum mg/L <0.1
    Water temperature[3] ℃ 5~45
    Note:
    [1] At the same time to meet the total dose of less than 1000 h.mg / L during the life of the membrane.
    [2] Iron oxidation rate depends on the iron content, dissolved oxygen concentration in water and water pH, when pH <6, dissolved oxygen <0.5mg/L, allowing the maximum Fe2+ <4mg/L.
    [3] Reverse osmosis unit of the optimal design of the water temperature of 20℃ ~ 25℃.

    Advantages

    • Broad removal of impurities: Capable of removing not only inorganic salt ions but also various organic impurities from water.
    • High desalination rate: No phase change during the water separation process, achieving a desalination rate of up to 99.7%.
    • Compact & Customizable: High water production capacity with compact equipment size, enabling skid-mounted installation or customization based on site dimensions.
    • Cost-effective operation: Low energy consumption, automatic operation, and minimal investment cost.
    • Eco-friendly & Adaptive: Strong adaptability, wide application range, and no environmental pollution.
    Reverse Osmosis System (3)

    Scope of Application

    As the core treatment equipment for water desalination systems, reverse osmosis equipment, when combined with pretreatment and subsequent desalination systems, has been widely applied in water treatment, electronics, chemicals, pharmaceuticals, food and beverages, metallurgy, and environmental protection sectors.

    Frequently Asked Questions

    What is the optimal water temperature for reverse osmosis equipment operation?
    The optimal design water temperature for the reverse osmosis unit is 20℃ to 25℃, with an acceptable operating range of 5℃ to 45℃. Standard capacity ratings are based on 25°C raw water.
    What is the typical desalination rate of this RO system?
    The system achieves a desalination efficiency of up to 99.7% without phase changes during separation, effectively filtering out inorganic salts, organic compounds, and microorganisms.
    What does the pretreatment system include?
    The pretreatment configuration typically includes a Multi-media Filter (for suspended solids), an Activated Carbon Filter (for chlorine and organics), and a Water Softener (to remove calcium and magnesium and prevent scale).
    What are the feed water quality requirements for the RO membranes?
    Feed water should maintain a Turbidity < 1.0 NTU, Silt Density Index (SDI) < 5, Free Residual Chlorine controlled to 0.0 mg/L (< 0.1 mg/L), and running pH between 4 and 11.
    Can the RO system be customized for specific industry standards?
    Yes, the system can be skid-mounted or dimension-customized with single-stage, double-stage, EDI systems, polishing mixed beds, or UV/ozone post-treatment to meet resistivity levels up to 18 MΩ·cm.
    Which industries can benefit from this reverse osmosis equipment?
    It is widely used across electronics, chemicals, pharmaceuticals, food & beverages, metallurgy, industrial water treatment, and environmental protection sectors.

    Leave Your Message