Leave Your Message

China Suppliers Factory Commercial Reverse Osmosis System for High-Purity Drinking Water Without Pretreatment

Reverse osmosis (RO) technology is a leading water purification solution provided by top China suppliers and factories. This cutting-edge equipment utilizes semi-permeable membrane technology to effectively eliminate impurities, including dissolved salts, organic matter, and bacteria, from water sources. The fundamental process involves applying pressure to drive water molecules through a reverse osmosis membrane (RO membrane) with an incredibly small pore size of 1/10,000 μm, effectively trapping pollutants and ensuring that the treated water meets strict physical, chemical, and hygiene standards required for drinking. The result is ultra-pure water, showcasing the highest level of purity achievable in modern water treatment technologies, reaching an impressive cleanliness level of almost 100%. For reliable water purification solutions, partner with trusted suppliers and factories in China to achieve the best results.

    Products Video

    Products Description

    RO equipment is currently one of the most advanced systems for producing pure water in global water treatment technology. It features low operating costs, economic efficiency, ease of operation, and reliable performance, making it the preferred choice for businesses requiring pure water production. The production capacity of RO equipment is based on raw water at 25°C, which represents the standard production condition. Variations in water temperature and production conditions may influence the equipment's output capacity.
    Industrial reverse osmosis equipment must be configured with different processes according to specific water quality requirements. Water standards vary across industries, such as resistivity levels ranging from 18 MΩ·cm to 0.5 MΩ·cm and conductivity ranging from 20 μS/cm to 0.1 μS/cm. Therefore, it is essential to configure appropriate pretreatment systems, single-stage or double-stage reverse osmosis processes, and post-treatment systems (e.g., EDI electric demineralization systems, polishing mixed bed systems, ultraviolet sterilization, ozone generators, chlorine dioxide systems, etc.) to meet these diverse standards.
    Reverse Osmosis System (1)
    Reverse Osmosis System (2)

    Major Components

    1. Pretreatment System
    • Multi-media Filter: Removes suspended solids, sediments, and other large particulate impurities.
    • Activated Carbon Filter: Adsorbs organic compounds, residual chlorine, odors, and other contaminants.
    • Softener: Eliminates calcium and magnesium ions from water to prevent scale formation.
    2. Reverse Osmosis Membrane

    Core component, typically constructed of polyamide or cellulose acetate materials, with an extremely small pore size (approximately 0.0001 microns). It effectively intercepts dissolved salts, bacteria, viruses, and other microorganisms.

    3. High-Pressure Pump

    Supplies sufficient pressure (generally ranging from 100 to 1000 psi) to enable water molecules to permeate through the reverse osmosis membrane.

    4. Post-treatment System
    • UV Sterilizer: Provides additional sterilization by eliminating bacteria and viruses.
    • Ozone Generator: Utilized for disinfection and odor removal processes.
    5. Control System
    • PLC Controller: Automates equipment operation and monitors parameters such as pressure, flow rate, and water quality.
    • Instruments: Devices such as pressure gauges, flow meters, and conductivity meters are employed for real-time monitoring and data collection.

    Products Specification

    Reverse osmosis feed water requirements
    Project Unit Indicator
    pH(25℃) 4~11 (running) 2~11 (cleaning)
    Turbidity NTU <1.0
    Silt Density Index (SDI) <5
    Free residual chlorine mg/L <0.1[1],Control to 0.0
    Iron mg/L <0.05(Dissolved oxygen >5mg/L)[2]
    Manganese mg/L <0.3
    Aluminum mg/L <0.1
    Water temperature[3] ℃ 5~45
    Note:
    [1] At the same time to meet the total dose of less than 1000 h.mg / L during the life of the membrane.
    [2] Iron oxidation rate depends on the iron content, dissolved oxygen concentration in water and water pH, when pH <6, dissolved oxygen <0.5mg/L, allowing the maximum Fe2+<4mg/L
    [3] Reverse osmosis unit of the optimal design of the water temperature of 20℃ ~ 25℃.

    Advantages

    • Broad removal of impurities: Capable of removing not only inorganic salt ions but also various organic impurities from water.
    • No phase change during the water separation process, achieving a high desalination rate (up to 99.7%).
    • High water production capacity with compact equipment size, enabling skid-mounted installation or customization based on site dimensions.
    • Low energy consumption, automatic operation, and minimal investment cost.
    • Strong adaptability, wide application range, and no environmental pollution.
    Reverse Osmosis System (3)

    Scope of Application

    As the core treatment equipment for water desalination systems, reverse osmosis equipment, when combined with pretreatment and subsequent desalination systems, has been widely applied in water treatment, electronics, chemicals, pharmaceuticals, food and beverages, metallurgy, and environmental protection sectors.

    Frequently Asked Questions

    Q: What is the optimal water temperature for designing a reverse osmosis unit?

    The optimal designed water temperature for a reverse osmosis unit is between 20°C and 25°C. While the system can operate in temperatures ranging from 5°C to 45°C, variations in water temperature will directly affect the output capacity.

    Q: What impurities can the RO membrane filter out, and what is its pore size?

    The reverse osmosis membrane is the core component of the system and typically features an extremely small pore size of approximately 0.0001 microns. It effectively intercepts dissolved salts, bacteria, viruses, and other micro-organic impurities, achieving a high desalination rate of up to 99.7%.

    Q: What are the feed water requirements for Silt Density Index (SDI) and Turbidity?

    For optimal and safe operation of the reverse osmosis system, the feed water turbidity must be less than 1.0 NTU, and the Silt Density Index (SDI) must be less than 5.

    Q: Why is a pretreatment system necessary for industrial RO equipment?

    A pretreatment system (consisting of a multi-media filter, activated carbon filter, and softener) is essential to remove suspended solids, organic compounds, chlorine, and hardness ions (calcium and magnesium). This protects the delicate RO membrane from scaling, fouling, and chemical degradation.

    Q: In which industries is reverse osmosis equipment commonly applied?

    RO systems are widely used as core desalination equipment across various sectors, including electronics (for high resistivity water), chemicals, pharmaceuticals, food and beverages, metallurgy, environmental protection, and general water treatment.

    Leave Your Message