Leave Your Message

China Reverse Osmosis Water Purification System Suppliers | Factory Direct RO for Drinking Water

Reverse osmosis (RO) is an advanced water purification system designed to deliver the highest quality of clean water by utilizing cutting-edge semi-permeable membrane technology. This innovative equipment effectively removes impurities such as dissolved salts, organic materials, and bacteria from water. By applying pressure, water molecules are forced through a reverse osmosis membrane (RO membrane) with an incredibly small pore size of 1/10,000 μm, allowing pollutants to be eliminated. This process ensures that the water produced meets stringent physical, chemical, and hygiene standards for safe drinking water. As a leading solution in water purification, reverse osmosis technology guarantees water purity levels that are nearly 100%. Our factory, a trusted name among China suppliers, specializes in providing high-quality reverse osmosis systems tailored to meet diverse needs.

    Products Video

    Products Description

    RO equipment is currently one of the most advanced systems for producing pure water in global water treatment technology. It features low operating costs, economic efficiency, ease of operation, and reliable performance, making it the preferred choice for businesses requiring pure water production. The production capacity of RO equipment is based on raw water at 25°C, which represents the standard production condition. Variations in water temperature and production conditions may influence the equipment's output capacity.
    Industrial reverse osmosis equipment must be configured with different processes according to specific water quality requirements. Water standards vary across industries, such as resistivity levels ranging from 18 MΩ·cm to 0.5 MΩ·cm and conductivity ranging from 20 μS/cm to 0.1 μS/cm. Therefore, it is essential to configure appropriate pretreatment systems, single-stage or double-stage reverse osmosis processes, and post-treatment systems (e.g., EDI electric demineralization systems, polishing mixed bed systems, ultraviolet sterilization, ozone generators, chlorine dioxide systems, etc.) to meet these diverse standards.
    Reverse Osmosis System (1)
    Reverse Osmosis System (2)

    Major Components

    • 1. Pretreatment System
      - Multi-media Filter: Removes suspended solids, sediments, and other large particulate impurities.
      - Activated Carbon Filter: Adsorbs organic compounds, residual chlorine, odors, and other contaminants.
      - Softener: Eliminates calcium and magnesium ions from water to prevent scale formation.
    • 2. Reverse Osmosis Membrane
      Core component, typically constructed of polyamide or cellulose acetate materials, with an extremely small pore size (approximately 0.0001 microns). It effectively intercepts dissolved salts, bacteria, viruses, and other microorganisms.
    • 3. High-Pressure Pump
      Supplies sufficient pressure (generally ranging from 100 to 1000 psi) to enable water molecules to permeate through the reverse osmosis membrane.
    • 4. Post-treatment System
      - UV Sterilizer: Provides additional sterilization by eliminating bacteria and viruses.
      - Ozone Generator: Utilized for disinfection and odor removal processes.
    • 5. Control System
      - PLC Controller: Automates equipment operation and monitors parameters such as pressure, flow rate, and water quality.
      - Instruments: Devices such as pressure gauges, flow meters, and conductivity meters are employed for real-time monitoring and data collection.

    Products Specification

    Reverse osmosis feed water requirements
    Project Unit Indicator
    pH(25℃)   4~11 (running) 2~11 (cleaning)
    Turbidity NTU <1.0
    Silt Density Index (SDI)   <5
    Free residual chlorine mg/L <0.1[1],Control to 0.0
    Iron mg/L <0.05(Dissolved oxygen >5mg/L)[2]
    Manganese mg/L <0.3
    Aluminum mg/L <0.1
    Water temperature[3] ℃ 5~45
    Note:
    [1] At the same time to meet the total dose of less than 1000 h.mg / L during the life of the membrane.
    [2] Iron oxidation rate depends on the iron content, dissolved oxygen concentration in water and water pH, when pH <6, dissolved oxygen <0.5mg/L, allowing the maximum Fe2+<4mg/L.
    [3] Reverse osmosis unit of the optimal design of the water temperature of 20℃ ~ 25℃.

    Advantages

    • Broad removal of impurities: Capable of removing not only inorganic salt ions but also various organic impurities from water.
    • No phase change during the water separation process, achieving a high desalination rate (up to 99.7%).
    • High water production capacity with compact equipment size, enabling skid-mounted installation or customization based on site dimensions.
    • Low energy consumption, automatic operation, and minimal investment cost.
    • Strong adaptability, wide application range, and no environmental pollution.
    Reverse Osmosis System (3)

    Scope of Application

    As the core treatment equipment for water desalination systems, reverse osmosis equipment, when combined with pretreatment and subsequent desalination systems, has been widely applied in water treatment, electronics, chemicals, pharmaceuticals, food and beverages, metallurgy, and environmental protection sectors.

    Frequently Asked Questions

    What are the primary operational benefits of RO equipment?
    RO equipment features low operating costs, high economic efficiency, ease of operation, and reliable performance, making it the preferred choice for businesses requiring pure water production.
    How does water temperature affect the capacity of reverse osmosis systems?
    The standard production capacity of RO equipment is calculated based on raw water at 25°C. Variations in water temperature and overall production conditions can directly influence the equipment's output capacity.
    Why is pretreatment necessary in a reverse osmosis system?
    Pretreatment prevents membrane scaling and fouling. It includes a multi-media filter to remove suspended solids, an activated carbon filter to adsorb organic compounds and chlorine, and a water softener to eliminate calcium and magnesium ions.
    What is the optimal water temperature design for reverse osmosis units?
    The optimal design water temperature for the reverse osmosis unit is between 20°C and 25°C, although the equipment can operate within a wider feed water temperature range of 5°C to 45°C.
    What desalination rate can reverse osmosis systems achieve?
    Reverse osmosis processes operate without a phase change during water separation and can achieve an exceptionally high desalination rate of up to 99.7%.
    Which industries commonly utilize reverse osmosis equipment?
    RO equipment is widely applied in water treatment, electronics, chemicals, pharmaceuticals, food and beverages, metallurgy, and environmental protection sectors.